How to see status of all disk arrays on HP Proliant Servers ?
Today in this article, we will see how to check the status of all disks on a HP Proliant server.
We will check it out both on server CLI and on its ILO.
1. Check the drive status on server using hpacucli utility.
root@ngelinux# hpacucli => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018A1AC999) Smart Array P812 in Slot 1 (sn: PAGXQ0BRH3O1999) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, OK) physicaldrive 5I:1:5 (port 5I:box 1:bay 5, SAS, 146 GB, OK) physicaldrive 6I:1:1 (port 6I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 5I:1:6 (port 5I:box 1:bay 6, SAS, 146 GB, OK, spare) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (410.1 GB, RAID 5, OK) physicaldrive 5I:1:7 (port 5I:box 1:bay 7, SAS, 146 GB, OK) physicaldrive 5I:1:8 (port 5I:box 1:bay 8, SAS, 146 GB, OK) physicaldrive 6I:1:2 (port 6I:box 1:bay 2, SAS, 146 GB, OK) physicaldrive 6I:1:3 (port 6I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 6I:1:4 (port 6I:box 1:bay 4, SAS, 146 GB, OK, spare) Enclosure SEP (Vendor ID HP, Model P812 INT EXP) 248 (WWID: 50014380240A0721, Box: 1) Expander 250 (WWID: 50014380240A0726, Box: 1) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 249 (WWID: 50014380240A073AS) => => ctrl all show status Smart Array P410i in Slot 0 (Embedded) Controller Status: OK Smart Array P812 in Slot 1 Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK =>
2. Take ILO console of the server and check Summary.
3. Now check drive status inside drives tab.